文献详情
Influence of Different Boundary Conditions in Finite Element Analysis on Pelvic Biomechanical Load Transmission
文献类型期刊
作者Hu, Pan[1];Wu, Tao[2];Wang, Hui-zhi[3];Qi, Xin-zheng[4];Yao, Jie[5];Cheng, Xiao-dong[6];Chen, Wei[7];Zhang, Ying-ze[8]
机构
通讯作者Zhang, YZ (reprint author), Third Hosp Hebei Med Univ, Emergency Ctr Trauma, Orthopaed Res Inst Hebei Prov, Dept Orthopaed Sur,Key Lab Orthopaed Biomech Hebe, Shijiazhuang 050051, Hebei, Peoples R China.
来源信息年:2017  卷:9  期:1  页码范围:115-122  
期刊信息ORTHOPAEDIC SURGERY影响因子和分区  ISSN:1757-7853
关键词Biomechanics; Finite element analysis; Pelvis
摘要Objective To observe the effects of boundary conditions and connect conditions on biomechanics predictions in finite element (FE) pelvic models. Methods Three FE pelvic models were constructed to analyze the effect of boundary conditions and connect conditions in the hip joint: an intact pelvic model assumed contact of the hip joint on both sides (Model I); and a pelvic model assumed the hip joint connecting surfaces fused together with (Model II) or without proximal femurs (Model III). The model was validated by bone surface strains obtained from strain gauges in an in vitro pelvic experiment. Vertical load was applied to the pelvic specimen, and the same load was simulated in the FE model. Results There was a strong correlation between the FE analysis results of Model I and the experimental results (R-2 = 0.979); meanwhile, the correlation coefficient and the linear regression function increased slightly with increasing load force. Comparing the three models, the stress values in the point near the pubic symphysis in Model III were 48.52 and 39.1% lower, respectively, in comparison with Models I and II. Furthermore, the stress values on the dome region of the acetabulum in Models II and III were 103.61 and 390.53% less than those of Model I. Besides, the posterior acetabular wall stress values of Model II were 197.15 and 305.17% higher than those of Models I and III, respectively. Conclusions These findings suggest that the effect of the connect condition in the hip joint should not be neglected, especially in studies related to clinical applications.
收录情况SCIE(WOS:000398214200017)  
所属部门生物与医学工程学院
DOI10.1111/os.12315
学科骨科
人气指数758
浏览次数758
基金Nature Science Foundation of China [81271975]
全部评论(0 条评论)
作者其他论文

Decoding the X(5568) as a Fully Open-Flavor su(b)over-bar(d)over-bar Tetraquark State.

Chen, Wei;Chen, Hua-Xing;Liu, Xiang,等.PHYSICAL REVIEW LETTERS.2016,117(2).

Long-term effects of placing one or two cages in instrumented posterior lumbar interbody fusion.

Zhang, Mingzheng;Pu, Fang;Xu, Liqiang,等.INTERNATIONAL ORTHOPAEDICS.2016,40(6),1239-1246.

Investigation of luminescence mechanism in La0.2Y1.8O3 scintillator.

Sahi, Sunil;Wang, Zhiqiang;Luo, Junming,等.JOURNAL OF LUMINESCENCE.2016,173,99-104.

The effect of fluid shear stress on the in vitro degradation of poly(lactide-co-glycolide) acid membranes.

Chu, Zhaowei;Zheng, Quan;Guo, Meng,等.JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A.2016,104(9),2315-2324.

Towards Exotic Hidden-Charm Pentaquarks in QCD.

Chen, Hua-Xing;Chen, Wei;Liu, Xiang,等.PHYSICAL REVIEW LETTERS.2015,115(17).

登录